PRECISION ENGINEERING · COLD-CHAIN EQUIPMENT
Fluorocarbon refrigeration unit
Parallel compressor configurations match cooling demand with staged capacity control.
Discuss this product ↗-
High efficiency
(1) If one compressor fails, the remaining compressors can continue operating.
(2) Fully automatic operation supports efficient performance and low running costs.
(3) Systems can be configured for refrigerants including R22, R134a, R404A and R507A. -
Energy efficiency
(1) Staged capacity control combines multiple compressors to match cooling output to actual demand.
(2) Carefully designed piping minimizes pressure losses and improves unit efficiency.
(3) An efficient main oil separator helps improve heat exchanger performance.
(4) Multiple suction branches support energy-efficient operating conditions. -
Reliable operation
(1) High-quality imported compressors and control valves support reliability and long service life.
(2) Parallel operation balances compressor running hours automatically. The source states a service-life increase of over 30% compared with a single-compressor unit.
(3) A condensing pressure stabilizer maintains a relatively steady pressure for stable system operation.
(4) An efficient gas-liquid separator and dedicated piping design help reduce the risk of liquid slugging.
(5) Protection covers phase loss, reverse phase, overvoltage, undervoltage, high and low oil pressure, high discharge pressure, low suction pressure, low liquid level and motor overload.
(6) Fault isolation allows other compressors to continue operating when one compressor fails, helping maintain production. -
Staged capacity control reduces electrical startup impact
Sequential, time-delayed compressor starting reduces the electrical impact on the customer’s power supply.
High-temperature reciprocating refrigeration units
| Unit model | HCP-3FM | HCP-4FM | HCP-5FM | HCP-7FM | HCP-10FM | HCP-15FM | HCP-20FM | HCP-25FM | HCP-30FM | HCP-40FM | HCP-50FM | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Compressor model | 2EES-3Y | 2CES-4Y | 4FES-5Y | 4DES-7Y | 4VES-10Y | 4PES-15Y | 4NES-20Y | 4HE-25Y | 4GE-30Y | 6GE-40Y | 6FE-50Y | |
| Evaporating temperature range | ℃ | -15~+10 | ||||||||||
| Power supply | AC 3Φ 380V 50HZ | |||||||||||
| Nominal cooling capacity | W | 7100 | 10490 | 11380 | 16780 | 21800 | 30200 | 36100 | 47600 | 56400 | 79400 | 96700 |
| Nominal compressor power | KW | 2.2 | 3 | 3.7 | 5.4 | 7.4 | 11 | 14.7 | 18.4 | 22 | 29.4 | 36.7 |
| Compressor starting current | A | 37 | 44.2 | 62.2 | 82.4 | 99 | 132 | 158 | 193 | 220 | 323 | 404 |
| Maximum compressor operating current | A | 7.8 | 9.4 | 10.8 | 15.9 | 21 | 31 | 37 | 45 | 53 | 78 | 92 |
| Crankcase heater power | W | 0~120 | 0~120 | 0~120 | 0~120 | 100 | 100 | 100 | 140 | 140 | 140 | 140 |
| Condenser motor power | W | 2*120 | 2*120 | 2*120 | 2*180 | 2*450 | 2*600 | 2*780 | 2*800 | 2*750 | 3*550 | 3*1100 |
| Protection devices | Standard: high/low differential pressure control, high discharge pressure, low suction pressure, low oil temperature and motor protection. Units above 20 HP include a high-pressure controller and oil differential pressure switch. |
|||||||||||
| Pipe connection sizes | Liquid line | 1/2* | 1/2* | 1/2* | 5/8* | 7/8* | 7/8* | 7/8* | 1-1/8* | 1-1/8* | 1-3/8* | 1-3/8* |
| Suction line | 7/8* | 7/8* | 7/8* | 1-1/8* | 1-3/8* | 1-5/8* | 1-5/8* | 2-1/8* | 2-1/8* | 2-1/8* | 2-1/8* | |
| Remarks: 1. Nominal cooling capacity is rated at −5/+45°C. 2. These data apply to R22 units; values differ with other refrigerants. 3. Technical data are for reference and may change without notice. |
||||||||||||
Low-temperature reciprocating refrigeration units
| Unit model | HCP-3FL | HCP-4FL | HCP-5FL | HCP-9FL | HCP-12FL | HCP-14FM | HCP-18FM | HCP-23FM | HCP-28FM | HCP-34FM | HCP-44FM | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Compressor model | 2CES-3Y | 4EES-4Y | 4DES-5Y | 4TES-9Y | 4PES-12Y | 4NES-14Y | 4HE-18Y | 4GE-23Y | 6HE-28Y | 6GE-34Y | 6FE-44Y | |
| Evaporating temperature range | ℃ | -5~-40 | ||||||||||
| Power supply | AC 3Φ 380V 50HZ | |||||||||||
| Nominal cooling capacity | W | 4480 | 6100 | 7060 | 10660 | 11760 | 14470 | 20600 | 24300 | 30300 | 36600 | 43500 |
| Nominal compressor power | KW | 2.2 | 3 | 3.7 | 5.88 | 7.35 | 8.82 | 11 | 14.7 | 18.4 | 22 | 29.4 |
| Compressor starting current | A | 37 | 53.2 | 62.2 | 81 | 99 | 113 | 132 | 158 | 193 | 220 | 323 |
| Maximum compressor operating current | A | 8.5 | 10.7 | 13.5 | 17 | 21 | 24 | 31 | 37 | 45 | 53 | 78 |
| Crankcase heater power | W | 0~120 | 0~120 | 0~120 | 0~120 | 100 | 100 | 100 | 140 | 140 | 140 | 140 |
| Condenser motor power | W | 1*120 | 1*120 | 2*120 | 2*120 | 2*180 | 2*180 | 2*450 | 2*450 | 2*600 | 3*780 | 3*800 |
| Protection devices | Standard: high/low differential pressure control, high discharge pressure, low suction pressure, low oil temperature and motor protection. Units above 15 HP include a high-pressure controller and oil differential pressure switch. |
|||||||||||
| Pipe connection sizes | Liquid line | 1/2* | 1/2* | 1/2* | 5/8* | 5/8* | 5/8* | 7/8* | 7/8* | 7/8* | 7/8* | 1-1/8* |
| Suction line | 7/8* | 1-1/8* | 1-1/8* | 1-3/8* | 1-3/8* | 1-3/8* | 1-5/8* | 2-1/8* | 2-1/8* | 2-1/8* | 2-1/8* | |
| Remarks: 1. Nominal cooling capacity is rated at −25/+45°C. 2. These data apply to R507A units; values differ with other refrigerants. 3. Technical data are for reference and may change without notice. |
||||||||||||
Two-stage reciprocating refrigeration units
| Unit model | HCP-5FD | HCP-8FD | HCP-12FD | HCP-16FD | HCP-20FD | HCP-25FD | HCP-30FD | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Compressor model | S4T-5 2Y | S4N-8 2Y | S4G-12 2Y | S6J-16 2Y | S6H-20 2Y | S6G-25 2Y | S6F-30 2Y | |||||
| Evaporating temperature range | ℃ | -35~-60 | ||||||||||
| Power supply | AC 3Φ 380V 50HZ | |||||||||||
| Nominal cooling capacity | W | 5140 | 7320 | 11680 | 16590 | 19150 | 21900 | 26000 | ||||
| Nominal compressor power | KW | 4 | 5.5 | 9.2 | 11 | 15 | 18.5 | 22 | ||||
| Compressor starting current | A | 39 | 49 | 69 | 81 | 97 | 116 | 135 | ||||
| Maximum compressor operating current | A | 14 | 17 | 24 | 31 | 37 | 45 | 53 | ||||
| Crankcase heater power | W | 100 | 100 | 140 | 140 | 140 | 140 | 140 | ||||
| Condenser motor power | W | 2*120 | 2*120 | 2*180 | 2*450 | 2*600 | 2*600 | 2*780 | ||||
| Protection devices | Standard: high/low differential pressure control, high discharge pressure, low suction pressure, low oil temperature and motor protection. Units above 15 HP include a high-pressure controller and oil differential pressure switch. |
|||||||||||
| Pipe connection sizes | Liquid line | 1/2* | 1/2* | 5/8* | 5/8* | 7/8* | 7/8* | 7/8* | ||||
| Suction line | 7/8* | 1-1/8* | 1-3/8* | 1-5/8* | 1-5/8* | 1-5/8* | 2-1/8* | |||||
| Remarks: 1. Nominal cooling capacity is rated at −40/+45°C. 2. These data apply to R507A units; values differ with other refrigerants. 3. Technical data are for reference and may change without notice. |
||||||||||||
Semi-hermetic screw refrigeration units
| Unit model | HCS-50L | HCS-60L | HCS-70L | HCS-75L | HCS-125L | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Compressor model | HSN6461-50 | HSN7451-60 | HSN7461-70 | HSN7471-75 | HSN8571-125 | |||||||
| Evaporating temperature range | ℃ | -20~-60 | ||||||||||
| Power supply | AC 3Φ 380V 50HZ | |||||||||||
| Nominal cooling capacity | W | 74300 | 91100 | 100300 | 105300 | 173400 | ||||||
| Nominal compressor power | KW | 37 | 44 | 52 | 55 | 92 | ||||||
| Compressor starting current | A | 206 | 267 | 290 | 350 | 612 | ||||||
| Maximum compressor operating current | A | 79 | 98 | 124 | 144 | 216 | ||||||
| Protection devices | Standard: high/low differential pressure control, high discharge pressure, low suction pressure, low oil temperature, motor protection, pressure control, oil flow detection and oil level detection. | |||||||||||
| Pipe connection sizes | Liquid line | 1-3/8* | 7/8* | 1-3/8* | 1-3/8* | 1-5/8* | ||||||
| Suction line | DN65 | DN80 | DN80 | DN80 | DN100 | |||||||
| Remarks: 1. Nominal cooling capacity is rated at −25/+35°C. 2. These data apply to R507A units; values differ with other refrigerants. 3. Technical data are for reference and may change without notice. |
||||||||||||
Two-stage screw refrigeration units
| Unit model | HCS-30D | HCS-50D | HCS-70D | HCS-100D | HCS-125D | HCS-150D | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Compressor model | SDL-120E | SDL-220E | SDL-330E | SDL-450E | SDL-550E | SDL-660E | ||||||
| Evaporating temperature range | ℃ | -30~-60 | ||||||||||
| Power supply | AC 3Φ 380V 50HZ | |||||||||||
| Nominal cooling capacity | W | 28120 | 51360 | 79450 | 107820 | 127960 | 153570 | |||||
| Nominal compressor power | KW | 22.05 | 36.75 | 55.1 | 73.5 | 91.8 | 110.25 | |||||
| Compressor operating current | A | 28.29 | 55.9 | 85.11 | 122.47 | 132.66 | 160.9 | |||||
| Economizer load | KW | 5.42 | 11.09 | 16.13 | 21.89 | 24.65 | 29.6 | |||||
| Oil cooling load | KW | 6.58 | 13.12 | 18.17 | 21.32 | 22.35 | 24.8 | |||||
| Protection devices | Standard: high/low differential pressure control, high discharge pressure, low suction pressure, low oil temperature, motor protection, pressure control, oil flow and level detection, and four-stage capacity control. | |||||||||||
| Pipe connection sizes | Liquid line | 7/8* | 1-1/8* | 1-3/8* | 1-3/8* | 1-5/8* | 1-5/8* | |||||
| Suction line | DN65 | DN80 | DN100 | DN125 | DN125 | DN150 | ||||||
| Remarks: 1. Nominal cooling capacity is rated at −42/+40°C. 2. These data apply to R507A units; values differ with other refrigerants. 3. Technical data are for reference and may change without notice. |
||||||||||||